None of my three drives have a terminator, resistor, I believe you are correct. That is how my ribbon cable is as well. I also have tested the voltage going to the floppy drive and it is 11.86 and 4.82 which is within spec.I expect the dip shunt to be set the same. In TRS-80 Model 1, 3, 4 4P, 4D, and CoCo, Tandy did the drive select in the ribbon cable connected to the drives ( removed the pins for the other drive selects), making each cable connector unique. It's possible the seek error occurs when there is a dead or missing floppy (I've not run through all possible scenarios, and I do not have a working 4P apart right now).
Neither drive in this setup has a terminator. I think the 4 series added termination/pullup at the main board (a little wrong, but simplifies things. This is an external pair of TM50s I had available).
You'll notice the cable connector is missing pins, that's how drive select is managed. (yours should be similar)
I powered on the 4-p without the drives attached and got the same message. I am leaning to thinking this is a problem with the 4-p not the drives.
Here is what I know
Ribbon cables selects the drives
Termination resistor is on main board?
Voltage going to drives is good
Both drives heads spin
The drives LED will light up for a fraction of a second before going dark
Drives will not move their heads at all
After the old drive shorted it will only show “seek error” when turned on. Unless I do a different command. (Memory test ect…)
Thoughts on this? I could be completely wrong in my reasoning here.
What else should I be checking to narrow it down?
My next steps
- replace the bad caps when my new ones come in
- install the gotek when the cables come in (thanks TUC)