• Please review our updated Terms and Rules here

Recent content by developstopfix

  1. D

    1702 Audio Issue

    For anyone who might come across this in the future because they're experiencing similar issues, it turned out to just be a bad AN5265 (IC601).
  2. D

    1702 Audio Issue

    I picked up a really clean 1702 yesterday from a seller on FB Marketplace. She was selling it for a family friend and wasn't sure if it even worked or not, so it was a bit of a gamble and I was fine with that. The good news is that the picture looks great and there's no issues there, at least...
  3. D

    "Upgrading" a VT101 to VT102?

    Figured I would check back in with an update. The seller was nice enough to send me a third VT102 terminal board and that one appears to be working just fine, so as I expected originally they're completely interchangeable.
  4. D

    "Upgrading" a VT101 to VT102?

    Hello everyone. A while back I had made a post or two on here in search of a VT100/101/102 etc. terminal. I ended up finding a nice VT101 and have been tinkering with it since. It is fully working, but the lack of AVO features on the 101 as well as slightly reduced performance compared to the...
  5. D

    VT1XX and flow control questions/issues

    Right now I'm using Debian Linux on an IBM workstation because it was the most convenient thing with an actual serial port that I had nearby. I thought about trying other hardware/OSs as well. And yeah, I figured configuring the serial console with stty would be enough. It definitely does work...
  6. D

    VT1XX and flow control questions/issues

    Well that is my main issue. The 101 works fine even at 19200 with flow control enabled on the host side, but some applications don't seem to use it at all and hence aren't usable. I'd be content with sticking to 9600bps if it worked 100%, and if that means finding a VT102 or VT131 then so be it...
  7. D

    VT1XX and flow control questions/issues

    I hadn't even considered the cable being an issue. I'm using a cheap, longer than necessary, cable and DB25 F to DE9 M adapter from Amazon, I'll see if I can dig up something nicer. I too would expect the VT101 should perform at least as well as the VT100, being a slightly newer and simplified...
  8. D

    VT1XX and flow control questions/issues

    I recently acquired a VT101 terminal and after considerable time and effort was spent cleaning it inside and out (mostly inside - from what I can tell it was used in some kind of tractor or farm equipment dealer's service center and it shows) it's humming along nicely. Well, mostly anyway. While...
  9. D

    Mid Atlantic WTB: DEC VT100/101/102/131/132

    Indeed I am. I thought about using another username that was more relevant to the topic of this board but couldn't come up with anything good off the top of my head. Anyway, thanks for having me.
  10. D

    Mid Atlantic WTB: DEC VT100/101/102/131/132

    I'm on the lookout for a DEC VT100 or similar model, complete with keyboard. Located in NYC/Northern NJ area but I'm willing to pay for shipping if necessary. I'll also be at VCF East of course so we could meet there as well.
Back